Customization: | Available |
---|---|
Material: | Plastic |
Usage: | for Experiment, for Manufacture, Ventilation Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Rated Voltage | 230 VAC |
Frequency | 50/60 Hz |
Operating Voltage | 200~242 VAC |
Capacitor
|
2μF/500 VAC
|
Rated Speed | 1600 RPM / 1500 RPM |
Input Current | 0.42 A / 0.47 A |
Input Power | 100 W / 110 W |
Air Flow |
330m3 /H / 305 m3 /H
|
Static Pressure |
320 Pa / 480 Pa
|
Acoustical Noise |
52 dB(A) /58 dB(A)
|
Life Expectance |
30,000 Hours
At nominal supply voltage, full speed room temperature 20ºC
|
Direction of Rotation
|
Clockwise seen on rotor
|
Insulation Class | Class F |
Protection Type | IP44 |
Thermal Protection
|
Cut off temperature:150-160ºC;replacement temperature;100-130ºC. |
Dimension |
See dimension drawing
|
Material of Impeller | PA66 |
Impeller Plate
|
Sheet-metal plate
|
Mounting Position
|
Any
|
Surface of Rotor
|
Coated in black
|
Bearing System
|
Ball bearing
|
Operating Temperature | -30ºC to 60ºC |
Storage Temperature | -10ºC to 40ºC |
Operating Humidity | 0% to 95% RH |
Storage Humidity | 0% to 75% RH |
Dustproof Test
|
Temperature range: 15ºC to 35ºC. 1mm diameter metal wire
cannot go through the gap between rotor cup and base.
Follow IEC 60529 IP4X.
|
Waterproof Test
|
Temperature range: 15ºC to 35ºC and duration of test: at least
10 minutes, to spray water from all direction (360°).
Follow IEC 60529 IPX4
|
RoHS
|
All the material meets RoHS standard.
|
Rated Voltage | 230 VAC |
Frequency | 50/60 Hz |
Operating Voltage | 198~242 VAC |
Capacitor
|
2μF/500 VAC
|
Rated Speed | 1600 RPM / 1200 RPM/ 900 RPM |
Input Current | 0.42 A / 0.3 A/ 0.2 A |
Input Power | 100 W / 65 W/ 40 W |
Air Flow |
325m3 /H / 250 m3 /H/ 175 m3 /H
|
Static Pressure |
360 Pa / 320 Pa/ 280 Pa
|
Acoustical Noise |
52 dB(A) / 40 dB(A)/ 32 dB(A)
|
Life Expectance |
30,000 Hours
At nominal supply voltage, full speed room temperature 20ºC
|
Direction of Rotation
|
Clockwise seen on rotor
|
Insulation Class | Class F |
Protection Type | IP44 |
Thermal Protection
|
Cut off temperature:150-160ºC;replacement temperature;100-130ºC. |
Dimension |
See dimension drawing
|
Material of Impeller | PA66 |
Impeller Plate
|
Sheet-metal plate
|
Mounting Position
|
Any
|
Surface of Rotor
|
Coated in black
|
Bearing System
|
Ball bearing
|
Operating Temperature | -30ºC to 60ºC |
Storage Temperature | -10ºC to 40ºC |
Operating Humidity | 0% to 95% RH |
Storage Humidity | 0% to 75% RH |
Dustproof Test
|
Temperature range: 15ºC to 35ºC. 1mm diameter metal wire
cannot go through the gap between rotor cup and base.
Follow IEC 60529 IP4X.
|
Waterproof Test
|
Temperature range: 15ºC to 35ºC and duration of test: at least
10 minutes, to spray water from all direction (360°).
Follow IEC 60529 IPX4
|
RoHS
|
All the material meets RoHS standard.
|
1. Where is your factory located?
Our factory is located in Suzhou City, China, about 60mins from Shanghai Airport by car. Warmly welcome to visit us!