Customization: | Available |
---|---|
Material: | Galvanized Metal Sheet |
Usage: | for Air Conditioner, for Manufacture, for Refrigerate, Heat Exchanger, Free Cooling Unit |
Still deciding? Get samples of US$ 59.6/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.General Characters
Model
|
PD3N146B48H |
Rated Voltage
|
48VDC
|
Operating Voltage
|
36~57VAC
|
Rated Speed
|
1580 RPM
|
Input Current
|
3.0A
|
Input Power
|
144W
|
Air Flow
|
960m3/H
|
Static Pressure
|
248 Pa
|
Sound Level
|
61 dB(A)
|
Protection Type
|
IP44
|
Dimension
|
209mm X219mm X270mm (see dimension drawing)
|
Material of Impeller
|
Propylene with glass-fiber reinforced
|
Mounting Position
|
Any
|
Surface of Rotor
|
Coated in black
|
Bearing System
|
NMB ball bearing
|
Lead Wire
|
D2
|
Weight
|
4500g
|
Package
|
Standard
|
Locked-rotor Protection
|
Over-current limiting circuit protects motor from damage at least for 72 hours of locked rotor condition at rated voltage.
|
under Locked Rotor |
A, Typical inrush current when the motor is trying to re-start under locked rotor conditions is 2~4 times the normal running
current reoccurring and for 16~20% of restarting cycle period. B, If he CL function is used this restarting inrush current is about the same as the normal running current. |
Reverse Polarity Protection
|
No damage if the positive and negative leads are reversed under maximum operation voltage conditions.
|
Over Voltage Protection
|
The circuit will be shut down automaticlly when input voltage over threshold. And re-started when Voltage down to threshold below.
|
Soft Start
|
In 5 seconds after power on and speed control voltage gets to 1.5V or PWM duty cycle at 10% above.
|
Certificate Show:UL / CE / Rohs
Application Scopes:Ventilation & Purification / Air Conditioning / Refrigeration / IT & Electronic Industry / Medical Industry / Heating / Automotive Industry / Household Electric Appliances / Cloud Date Center / Mechanical Equipment and Systems.
About PBM:High Quality EC Fan / Competitive Price / Strong Team / Long Life Expectance / Fast Delivery / Customization Available / Attentive Service / Professional Assistance
Q: What are electronically commutated motors?
Electronically Commutated motors are brushless DC motors where the direction of the electric current is switched using electronic controllers. As the switching of the current is technically known as 'commutating', brushless motors are also called 'electronically commutated' motors. EC motors provide the advantages of brushed DC motors in terms of the ability to have variable speed control, but without the drawbacks of brushes.